TIdTelnet
是一个多线程组件.它有一个内部线程,可以从套接字连续读取,TIdTelnet.OnDataAvailable
每当有数据缓冲区可用时触发事件.
TIdTelnet
是TIdTCPClient
后代.查看IdTelnet.pas源文件以了解它是如何实现的.您可以在自己的代码中执行类似的操作,TIdIOHandler.ReadLn()
在您自己的线程中调用,例如:
type
TMyThread = class(TThread)
private
FConn: TIdTCPConnection;
protected
procedure Execute; override;
public
constructor Create(AConn: TIdTCPConnection); reintroduce;
end;
constructor TMyThread.Create(AConn: TIdTCPConnection);
begin
inherited Create(False);
FConn := AConn;
end;
procedure TMyThread.Execute;
var
S: String;
begin
while not Terminated do
begin
S := FConn.IOHandler.ReadLn(...);
...
end;
end;
var
Thread: TMyThread = nil;
procedure TForm1.ConnectButtonClick(Sender: TObject);
begin
IdTCPClient1.Connect;
try
Thread := TMyThread.Create(IdTCPClient1);
except
IdTCPClient1.Disconnect;
raise;
end;
end;
procedure TForm1.DisconnectButtonClick(Sender: TObject);
begin
if Assigned(Thread) then Thread.Terminate;
try
IdTCPClient1.Disconnect;
finally
if Assigned(Thread) then
begin
Thread.WaitFor;
FreeAndNil(Thread);
end;
end;
end;
Run Code Online (Sandbox Code Playgroud)
如果您不想使用线程,则可以使用计时器.为了确保您的计时器线程(例如主线程)没有被不必要地阻塞,TIdIOHandler.CheckForDataOnSource()
只要TIdIOHandler.InputBuffer
空的时候使用带有小超时的方法,然后TIdIOHandler.ReadLn()
在数据可用时调用,例如:
procedure TForm1.ConnectButtonClick(Sender: TObject);
begin
IdTCPClient1.Connect;
ReadTimer.Enabled := True;
end;
procedure TForm1.DisconnectButtonClick(Sender: TObject);
begin
ReadTimer.Enabled := False;
IdTCPClient1.Disconnect;
end;
procedure TForm1.ReadTimerElapsed(Sender: TObject);
var
S: String;
begin
if IdTCPClient1.IOHandler.InputBufferIsEmpty then
begin
IdTCPClient1.IOHandler.CheckForDataOnSource(10);
if IdTCPClient1.IOHandler.InputBufferIsEmpty then Exit;
end;
S := IdTCPClient1.IOHandler.ReadLn(...);
...
end;
Run Code Online (Sandbox Code Playgroud)