无法使 Modelica 标准库中的泵工作

Luk*_*e83 3 modelica openmodelica

我想通过泵系统 (Pompa) 从水源 (Pozzetto) 抽取水来填充开放式水箱 (bacinella2)。问题很简单,但我无法在openmodelica中实现。

我试图消除泵,直接连接两个管道tubo1和tubo2,并且系统工作,这就是为什么我认为错误在泵对象中。

model Pompaggio


Modelica.Fluid.Machines.ControlledPump Pompa(
    redeclare package Medium = Modelica.Media.Water.StandardWater,
    //N_nominal=1500,
    use_T_start=true,
    T_start=Modelica.SIunits.Conversions.from_degC(40),
    m_flow_start=0.1,
    control_m_flow=true,
    allowFlowReversal=false,
    p_a_start=110000,
    p_b_start=130000,
    p_a_nominal=110000,
    p_b_nominal=130000,
    m_flow_nominal=0.1
    );


  Modelica.Fluid.Sources.Boundary_pT Pozzetto(redeclare package Medium = Modelica.Media.Water.StandardWater,
    nPorts = 1, T=Modelica.SIunits.Conversions.from_degC(40), p = 101325  );

  Modelica.Fluid.Vessels.OpenTank bacinella2(redeclare package Medium = Modelica.Media.Water.StandardWater,
    crossArea = 4, height = 100, level(start = 0.01), nPorts = 1,
    portsData = {Modelica.Fluid.Vessels.BaseClasses.VesselPortsData(diameter = 0.1)}, use_portsData = true);

  Modelica.Fluid.Pipes.StaticPipe tubo1(redeclare package Medium = Modelica.Media.Water.StandardWater,
    allowFlowReversal = true, diameter = 0.1, height_ab = 0, isCircular = true, length = 200, nParallel = 1);

  Modelica.Fluid.Pipes.StaticPipe tubo2(redeclare package Medium = Modelica.Media.Water.StandardWater,
    allowFlowReversal = true, diameter = 0.1, height_ab = 0, isCircular = true, length = 200, nParallel = 1);

equation
  connect(Pozzetto.ports[1], tubo1.port_a);
  connect(Pompa.port_a, tubo1.port_b);
  connect(Pompa.port_b, tubo2.port_a);
  //connect( tubo1.port_b, tubo2.port_a);
  connect(bacinella2.ports[1], tubo2.port_b);


end Pompaggio;
Run Code Online (Sandbox Code Playgroud)

有人可以帮助我吗?谢谢

Mar*_* A. 5

该模型的工作原理与 Dymola 中的一样。它给出了一些警告,导致在 OpenModelica 中解决问题。该模型实际上有两个“问题”:

  1. 的起始值bacinella2: 将值设置为T_start(start=293.15)ports(p(start={101422.89174430574})))可避免介质压力过低的警告。但实际上这并不能解决翻译过程中出现的原始模型的问题。
  2. 设置stateSelectPompa.medium。Dymola 输出警告,将设置从 更改为StateSelect.preferStateSelect.default因为它们无法区分。这是为Pompa.medium.h和完成的Pompa.medium.p。似乎 OpenModelica 无法自动执行此操作,因此似乎有必要手动更改它。

下面的代码是您的示例的扩展,具有上述两个更改。它在 OpenModelica 1.13.2(64 位)中进行了测试并且运行良好。

model Pompaggio_modified

Modelica.Fluid.Machines.ControlledPump Pompa(
    redeclare package Medium = Modelica.Media.Water.StandardWater,
    medium(h(stateSelect = StateSelect.default), p(stateSelect = StateSelect.default)),
    use_T_start=true,
    T_start=Modelica.SIunits.Conversions.from_degC(40),
    m_flow_start=0.1,
    control_m_flow=true,
    allowFlowReversal=false,
    p_a_start=110000,
    p_b_start=130000,
    p_a_nominal=110000,
    p_b_nominal=130000,
    m_flow_nominal=0.1);
    //N_nominal=1500,

  Modelica.Fluid.Sources.Boundary_pT Pozzetto(redeclare package Medium = Modelica.Media.Water.StandardWater,
    nPorts = 1, T=Modelica.SIunits.Conversions.from_degC(40), p = 101325);

  Modelica.Fluid.Vessels.OpenTank bacinella2(redeclare package Medium = Modelica.Media.Water.StandardWater,
    crossArea = 4, height = 100, level(start = 0.01), nPorts = 1,
    portsData = {Modelica.Fluid.Vessels.BaseClasses.VesselPortsData(diameter = 0.1)}, use_portsData = true,
    T_start(start=293.15),
    ports(p(start={101422.89174430574})));

  Modelica.Fluid.Pipes.StaticPipe tubo1(redeclare package Medium = Modelica.Media.Water.StandardWater,
    allowFlowReversal = true, diameter = 0.1, height_ab = 0, isCircular = true, length = 200, nParallel = 1);

  Modelica.Fluid.Pipes.StaticPipe tubo2(redeclare package Medium = Modelica.Media.Water.StandardWater,
    allowFlowReversal = true, diameter = 0.1, height_ab = 0, isCircular = true, length = 200, nParallel = 1);

equation 
  connect(Pozzetto.ports[1], tubo1.port_a);
  connect(Pompa.port_a, tubo1.port_b);
  connect(Pompa.port_b, tubo2.port_a);
  //connect( tubo1.port_b, tubo2.port_a);
  connect(bacinella2.ports[1], tubo2.port_b);

  annotation (uses(Modelica(version="3.2.3")));
end Pompaggio_modified;
Run Code Online (Sandbox Code Playgroud)