Den*_*nis 10 .net c# vb.net log4net
我想写信给Console.Out当我做任何事以下logger.Warn,然后我想写信给Console.Err当我登录任何logger.Error以上.我该如何编写我的log4net配置文件?
到目前为止,我有:
<?xml version="1.0" encoding="utf-8"?>
<log4net>
      <appender name="ConsoleAppender" type="log4net.Appender.ConsoleAppender">
        <layout type="log4net.Layout.PatternLayout">
          <conversionPattern value="%date [%thread] %-5level %logger [%property{NDC}] - %message%newline" />
        </layout>
      </appender>
      <root>
         <level value="DEBUG" />
         <appender-ref ref="ConsoleAppender" />
      </root>
</log4net>
Joe*_*Joe 14
您可以创建两个appender,并以不同方式配置它们.像(未经测试)的东西:
<log4net>
<appender name="ConsoleOutAppender" type="log4net.Appender.ConsoleAppender">
    <filter type="log4net.Filter.LevelRangeFilter">
        <levelMin value="DEBUG" />
        <levelMax value="WARN" />
    </filter>       
    <layout type="log4net.Layout.PatternLayout">
        <conversionPattern value="..."  />
    </layout>
</appender>
<appender name="ConsoleErrorAppender" type="log4net.Appender.ConsoleAppender">
    <filter type="log4net.Filter.LevelRangeFilter">
        <levelMin value="ERROR" />
        <levelMax value="FATAL" />
    </filter>       
    <target value="Console.Error" />
    <layout type="log4net.Layout.PatternLayout">
        <conversionPattern value="..." />
    </layout>
</appender>
<root>
    <level value="DEBUG" />
    <appender-ref ref="ConsoleOutAppender" />
    <appender-ref ref="ConsoleErrorAppender" />
</root>
</log4net>
编辑:修正逻辑错误与levelMin对比levelMax.