Bra*_*ers 6 windows performance smb file
我正在读取一个文件,我要么读取一行数据(1600个连续读取17个字节)或一列数据(1600个读取17个字节,由1600*17 = 27,200个字节分隔).该文件位于本地驱动器或远程驱动器上.我做了10次读取,所以我希望在每种情况下读取272,000字节的数据.
在当地的车道上,我看到了我的期望.在按顺序阅读的远程驱动器上,我也看到了我的期望,但在读取列时,我看到正在进行大量的额外读取.它们长度为32,768字节,似乎没有使用,但它们使读取的数据量从272,000字节跳到79 MB到106 MB.以下是使用Process Monitor的输出:
1:39:39.4624488 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,390,069, Length: 17 1:39:39.4624639 PM DiskSpeedTest.exe 89628 FASTIO_CHECK_IF_POSSIBLE \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Operation: Read, Offset: 9,390,069, Length: 17 1:39:39.4624838 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,388,032, Length: 32,768, I/O Flags: Non-cached, Paging I/O, Synchronous Paging I/O, Priority: Normal 1:39:39.4633839 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,417,269, Length: 17 1:39:39.4634002 PM DiskSpeedTest.exe 89628 FASTIO_CHECK_IF_POSSIBLE \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Operation: Read, Offset: 9,417,269, Length: 17 1:39:39.4634178 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,444,469, Length: 17 1:39:39.4634324 PM DiskSpeedTest.exe 89628 FASTIO_CHECK_IF_POSSIBLE \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Operation: Read, Offset: 9,444,469, Length: 17 1:39:39.4634529 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,441,280, Length: 32,768, I/O Flags: Non-cached, Paging I/O, Synchronous Paging I/O, Priority: Normal 1:39:39.4642199 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,471,669, Length: 17 1:39:39.4642396 PM DiskSpeedTest.exe 89628 FASTIO_CHECK_IF_POSSIBLE \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Operation: Read, Offset: 9,471,669, Length: 17 1:39:39.4642582 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,498,869, Length: 17 1:39:39.4642764 PM DiskSpeedTest.exe 89628 FASTIO_CHECK_IF_POSSIBLE \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Operation: Read, Offset: 9,498,869, Length: 17 1:39:39.4642922 PM DiskSpeedTest.exe 89628 ReadFile \\BCCDC01\BCC-raid3\SeisWareInc Temp Dir\BPepers_Temp\Projects\PT_4\Horizons\BaseName3D_1\RR_AP SUCCESS Offset: 9,498,624, Length: 32,768, I/O Flags: Non-cached, Paging I/O, Synchronous Paging I/O, Priority: Normal
请注意额外读取32,768,I/O标志设置为非缓存,寻呼I/O,同步寻呼I/O,优先级:正常.这些额外的读取是从272 KB到106 MB,并导致缓慢.从本地文件读取或者我正在读取一行时它们不会发生,因此它们都是顺序的.
我已经尝试过设置FILE_FLAG_RANDOM_ACCESS,但它似乎没有帮助.关于什么导致这些额外读取以及如何使它们停止的任何想法?
测试正在Vista 64位系统上运行.我可以提供程序的源代码来演示问题以及执行测试的控制台程序.
小智 2
您可能会遇到 smb 上的操作锁定问题。通常,当通过网络读取/保存文件时,Windows 会将完整文件拉到客户端进行处理并发回更改。当您使用平面文件数据库或文件时,可能会导致跨 smb 文件共享进行不必要的读取。
我不确定是否有一种方法可以拉取整个文件,从本地副本上的该文件中读取行,然后推回更改。
您将读到一些关于机会锁和平面文件数据库的噩梦。
http://msdn.microsoft.com/en-us/library/aa365433%28VS.85%29.aspx
不确定这是否能解决您的问题,但它可能会为您指明正确的方向。祝你好运!