小编gil*_*esw的帖子

惠普智能阵列;如何安全地从阵列中移除具有 SMART 预测性故障的物理驱动器,以便进行更换?

hpacucli 控制器插槽=1 ld 1 显示详细信息

Smart Array P400 in Slot 1

   array A

      Logical Drive: 1
         Size: 273.3 GB
         Fault Tolerance: RAID 1+0
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 65535
         Stripe Size: 128 KB
         Status: OK
         Array Accelerator: Enabled
         Unique Identifier: xxxx
         Disk Name: /dev/cciss/c0d0
         Mount Points: /boot 196 MB, / 7.8 GB
         Logical Drive Label: xxxxx
         Mirror Group 0:
            physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 72 GB, Predictive Failure)
            physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 72 …
Run Code Online (Sandbox Code Playgroud)

linux raid hp hp-smart-array hp-proliant