Mar*_*tin 2 hp-smart-array hardware-raid hp-proliant
我有一个HP Smart Array P400 RAID控制器,在 RAID 5 中配置了六个物理磁盘。其中四个物理磁盘处于“正常”状态,一个处于“预测性故障”状态,一个处于“备用”状态:
logicaldrive 1 (3.6 TB, RAID 5, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 1 TB, Predictive Failure)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 1 TB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 1 TB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 1 TB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 1 TB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 1 TB, OK, spare)
Run Code Online (Sandbox Code Playgroud)
将 ( hpacucli controller slot=6 array A add drives=1:6
) 一个“备用”驱动器添加到 RAID 5是否安全,一旦其驱动器类型从“备用驱动器”更改为“数据驱动器”,然后移除(物理上或可能使用hpacucli controller slot=6 array A remove drives=1:1
)具有“预测性故障”状态的 HDD ?
归档时间: |
|
查看次数: |
9216 次 |
最近记录: |