SMART 错误,190 Airflow_Temperature_Cel ,有风险吗?

Moh*_* OK 2 hardware linux hard-drive centos

拜托,我收到了 SMART 的这份报告

Checking /dev/sdb....
Errors:
 Please note the following marginal Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
190 Airflow_Temperature_Cel 0x0022   073   037   045    Old_age   Always   In_the_past 27 (3 44 30 26 0)

Checking /dev/sdc....
Errors:
 Please note the following marginal Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
190 Airflow_Temperature_Cel 0x0022   073   038   045    Old_age   Always   In_the_past 27 (0 181 30 26 0)

Checking /dev/sdd....
Errors:
 Please note the following marginal Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
190 Airflow_Temperature_Cel 0x0022   071   040   045    Old_age   Always   In_the_past 29 (1 6 32 27 0)
Run Code Online (Sandbox Code Playgroud)

请问,这是一个严重的错误吗?将来可能会导致问题?

Mic*_*ton 11

在过去的某个时间,您的驱动器记录的气温分别为 63、62 和 60 度。驱动器当前报告的温度为 27、27 和 29 度。该属性在 55 度时报警。(这些值的计算方法是从 100 中减去 VALUE、WORST 和 THRESH 列中的原始值。)

除非您在服务器中安装了其他温度监视器,或者您对服务器环境有其他了解,否则无法确定这种情况何时发生或持续了多长时间。

可能,将驱动器没有永久性的损害,如果热事件是一个持续时间短。但是这些驱动器将来可能更容易出现故障,尤其是当它们再次变得太热时。

您可以设置 smartd 来监控驱动器的 SMART 属性,并在发生任何重大事件时向您发送电子邮件。或者您可以使用其他监控系统,例如 nagios、zabbix 等。如果您的服务器是 HP ProLiant 或 Dell PowerEdge 等企业级服务器,它还将包含可以通过电子邮件或 SNMP 陷阱通知您问题的监控工具。