6 磁盘突袭 1+0

Mat*_*att 5 storage hp hp-smart-array hp-proliant raid10

我有一个HP Smart Array P400i RAID 控制器,有6 个磁盘,在 RAID 1+0 中工作。这是它的样子:

     Mirror Group 0:
        physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK)
        physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK)
        physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK)
     Mirror Group 1:
        physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK)
        physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 72 GB, OK)
        physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 72 GB, OK)
Run Code Online (Sandbox Code Playgroud)

如果我的理解是正确的,驱动器 1 和驱动器 2 可能会出现故障,而 RAID 仍然可以。

这对我来说似乎不对,我在想一个 RAID 1+0,有 6 个驱动器应该是这样的:

     Mirror Group 0:
        physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK)
        physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK)
     Mirror Group 1:
        physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK)
        physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK)
     Mirror Group 2:
        physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 72 GB, OK)
        physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 72 GB, OK)
Run Code Online (Sandbox Code Playgroud)

数据将跨 3 个镜像对进行条带化。

两种配置都可能,还是只有第一种?

eww*_*ite 2

您无法选择驱动器布置/对。

在这种安排中,HP Smart Array 控制器按如下方式分割磁盘:

physicaldrive 1I:1:1 pairs to physicaldrive 1I:1:4 
physicaldrive 1I:1:2 pairs to physicaldrive 2I:1:5
physicaldrive 1I:1:3 pairs to physicaldrive 2I:1:6 
Run Code Online (Sandbox Code Playgroud)

RAID 1+0 == RAID 1 对,条带化 (RAID 0) 在一起...

您可能会从上面列出的每个配对中丢失一个磁盘。或者,每个“镜像组”有一个驱动器。

另外:广泛使用的不同 RAID 级别有哪些?我何时应该考虑它们?

  • 控制器的输出对我来说似乎违反直觉。但你是对的。我杀死了驱动器 1、2 和 3,一​​切都还好。所以1是4的镜像,2是5的镜像,3是6的镜像。这就是我想要的设置。 (2认同)