我正在构建一个小型 NAS 服务器,主板是Intel D2700MUD(无风扇),PSU 是“Ace Outburst 480W”。安装 Ubuntu Server 后,我安装了 lm-sensors。输出:
coretemp-isa-0000
Adapter: ISA adapter
Core 0: +38.0 C (high = +80.0 C, crit = +100.0 C)
Core 1: +33.0 C (high = +80.0 C, crit = +100.0 C)
w83627dhg-isa-0290
Adapter: ISA adapter
Vcore: +1.22 V (min = +0.00 V, max = +1.74 V)
in1: +1.02 V (min = +0.58 V, max = +1.06 V)
AVCC: +3.38 V (min = +2.78 V, max = +0.64 V) ALARM
+3.3V: +3.38 V (min = +0.82 V, max = +0.59 V) ALARM
in4: +1.03 V (min = +1.25 V, max = +0.42 V) ALARM
in5: +1.52 V (min = +1.78 V, max = +0.51 V) ALARM
in6: +1.02 V (min = +0.16 V, max = +0.10 V) ALARM
3VSB: +3.34 V (min = +1.65 V, max = +1.15 V) ALARM
Vbat: +3.22 V (min = +2.34 V, max = +1.02 V) ALARM
fan1: 0 RPM (min = 2109 RPM, div = 128) ALARM
fan2: 0 RPM (min = 458 RPM, div = 128) ALARM
fan3: 0 RPM (min = 234 RPM, div = 128) ALARM
fan4: 0 RPM (min = 659 RPM, div = 128) ALARM
fan5: 0 RPM (min = 5273 RPM, div = 128) ALARM
temp1: +44.0 C (high = +35.0 C, hyst = +32.0 C) ALARM sensor = diode
temp2: +110.5 C (high = +80.0 C, hyst = +75.0 C) ALARM sensor = diode
temp3: +30.5 C (high = +80.0 C, hyst = +75.0 C) sensor = diode
cpu0_vid: +2.050 V
Run Code Online (Sandbox Code Playgroud)
我是否需要担心 in4,in5,in6.. 或 temp1/temp2 上的电压警报?
限制配置不正确,它们可能是默认值或来自其他板。例如:
+3.3V: +3.38 V (min = +0.82 V, max = +0.59 V)
对于 3.3V 电源来说,这看起来很合理,但完全超出了限制,而且最大值低于最小值!
temp2 看起来有点令人担忧,但这也可能是传感器配置错误。